Complaint

#202665684

Date last observed: 25-oct-26; unit: 202; exact location: main bldg; building ty
Filed

Location

Parcel 3779133 · South of Market · Supervisor District 6

Status timeline

  1. Nov 13, 2026 Filed

Description

Date last observed: 25-oct-26; unit: 202; exact location: main bldg; building type: residence/dwelling fire safety/fire escape; no access to breakers or fuses; no access to breakers or fuses; other electrical; ; additional information: nec 334.80 & 310.15, • nec table 310.15(c)(1), 21 to 30 conductors require a 45% derating factor, meaning 12 awg wire is only safely rated for 13.5 amps—less than a third of the 41–47 amps described,improper parallel bonding & ground loops (nec 250.6): under nec 250.148, all equipment grounding conductors spliced inside a metal box must be connected together and bonded to the box,,nec 240.24(b) (occupant access to overcurrent devices),nec 250.24(a)(5) & 250.6 (downstream neutral-to-ground bond / objectionable current,nec & cec article 210.25(a) (dwelling unit branch circuits,nec & cec article 210.25(b) (common area/other tenant loads,)-3) california code of regulations title 24, part 6 (energy code,california civil code § 1940.9; ,nec& cec

Inspection details

Division: Electrical Inspection Division
Receiving: Building Inspection Division
Status: Active